The SM930 Screening Memory audiometer is equipped with many useful features making it extremely advanced and at the same time focusing on ease of use. The SM930 Screening Memory audiometer contains a storage capacity of 83 audiograms that may be stored for later printout or transfer to patient file. The recorded values are stored in the internal memory, and kept even if the unit is turned off.
Along with your SM930 Screening Memory audiometer you may use the software program AudioConsole designed by Inmedico. AudioConsole is easy to use and makes it possible for the users to create their own patient file system. Additionally the SM930 Screening Memory audiometer may transfer test results in a format, which makes it possible to use already existing patient file systems.
When printing or transferring data to a computer, the device automatically selects the correct symbols for left or right ear. Additionally you may choose manual or automatic transfer/printing.
If you want a printout you may perform it just after a finished test OR you can wait until later, when it is convenient - the audiometer has stored all values.
You may follow the results on the screen during the test in two ways: each time you press the DATA button, or AUTOMATICALLY by using one of the set-up functions.
All functions are controlled by an advanced microprocessor, which offers stability and durability. The built-in tone generator is crystal driven avoiding distortion and making it insensitive to temperature fluctuations.
The SM930 Screening Memory audiometer may perform either manual or fully automatic hearing test, having four automatic tests allowing individually designed threshold test.
Aluminium cabinet provides a neat product, which at the same time is very sturdy and protects in the best way against any environmental influences from other electronic equipment; as aluminium protects against electromagnetic interference.
Kit includes Headset, Response Button and Carry case.
Along with your SM930 Screening Memory audiometer you may use the software program AudioConsole designed by Inmedico. AudioConsole is easy to use and makes it possible for the users to create their own patient file system. Additionally the SM930 Screening Memory audiometer may transfer test results in a format, which makes it possible to use already existing patient file systems.
When printing or transferring data to a computer, the device automatically selects the correct symbols for left or right ear. Additionally you may choose manual or automatic transfer/printing.
If you want a printout you may perform it just after a finished test OR you can wait until later, when it is convenient - the audiometer has stored all values.
You may follow the results on the screen during the test in two ways: each time you press the DATA button, or AUTOMATICALLY by using one of the set-up functions.
All functions are controlled by an advanced microprocessor, which offers stability and durability. The built-in tone generator is crystal driven avoiding distortion and making it insensitive to temperature fluctuations.
The SM930 Screening Memory audiometer may perform either manual or fully automatic hearing test, having four automatic tests allowing individually designed threshold test.
Aluminium cabinet provides a neat product, which at the same time is very sturdy and protects in the best way against any environmental influences from other electronic equipment; as aluminium protects against electromagnetic interference.
Kit includes Headset, Response Button and Carry case.
Frequencies: 11 fixed frequencies from 125 Hz to 8000 Hz.
Hearing Level Range: -10 dB to 110 dB in 5 dB steps.
Maximum Intensities
Program: Manual or automatic test
Serial interface: Manual or automatic transfer - 9600 baud
Calibration: Calibration data stored in programmable memory (EN60645 -1)
Power supply: Mains adapter for 220-240 V AC
Dimensions: 295mm x 180mm x 55mm
Weight: Approx. 1 kg
Standard accessories: TDH-39 earphones, SILENTA noise reducing headset, patient response, mains adapter
Optional extras: Carrying bag, PC cable, Printer cable, AudioConsole
Printer requirements: Printer with a Centronics parallel port (IEEE 1284-compatibel), which supports: HP PCL2-PCL5, Epson 9-24 pin graphics or IBM ProPrinter.
Hearing Level Range: -10 dB to 110 dB in 5 dB steps.
Maximum Intensities
Frequencies (Hz) | 125 | 250 | 500 | 750 | 1000 | 1500 | 2000 | 3000 | 4000 | 6000 | 8000 |
Air conduction (dB) | 70 | 90 | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 100 | 90 |
Program: Manual or automatic test
Serial interface: Manual or automatic transfer - 9600 baud
Calibration: Calibration data stored in programmable memory (EN60645 -1)
Power supply: Mains adapter for 220-240 V AC
Dimensions: 295mm x 180mm x 55mm
Weight: Approx. 1 kg
Standard accessories: TDH-39 earphones, SILENTA noise reducing headset, patient response, mains adapter
Optional extras: Carrying bag, PC cable, Printer cable, AudioConsole
Printer requirements: Printer with a Centronics parallel port (IEEE 1284-compatibel), which supports: HP PCL2-PCL5, Epson 9-24 pin graphics or IBM ProPrinter.