Health, Safety and Environmental Instruments and Meters

GA2003 HARM Vibration Meter

£985.00

Quick Overview

Simple to use Vibration Meter with Hand-Arm (HARM) filter for quick and easy measurements of hand-arm vibration
GA2003 Hand Arm Vibration Meter

True to the principles of Castle design and development strategy, we are proud to introduce the GA2003 pocket HARM® (Hand Arm Risk Measurement) Vibration Indicator. Offering simple, reliable and accurate results for many types of vibration measurement plus instant Data-logging.

Vibration Indicator

Damage to the Hand and Arm through exposure to vibrating hand held power tools is rapidly becoming a major area of health and safety risk assessment. Up to now, the process of gathering data to support such a program has been both difficult and costly. The GA2003 is a basic indicator for gathering background information to help determine whether or not there is a problem with Hand Arm vibration exposure in the workplace. For companies requiring measurement in compliance with the relevant international standards, then the Castle Excieo is designed specifically for this task.

Applications

The GA2003 is suitable for industrial vibration measurements, machine condition, building vibration and Hand Arm vibration indicative measurements.

Features

  • Small and Light weight
  • Simple to Use
  • Highly Robust
  • Tactile Keypad
  • 8 Character LCD Display
  • Simple Data-logging of 9 Data-points
  • Comes complete with Accelerometer, Cable and HARM BLOK®
  • Multiple Filters (Mechanical and HARM®)
  • Multiple Parameters (Acceleration, Velocity and HARM®)
  • Multiple Measurements (Lav, rms, Max.rms. and Peak & Elapsed Time)


What do You Get?

The GA2003 comes with slightly different accessories to suit the nature of the work that would normally be carried out. The accessories available widen the applications to cover those of the GA2002 and make this a truly Multi Function Instrument.

  • Items Included:
  • GA2003 HARM®/Gen. Purpose Pocket Vibration Meter.
  • KD1001 Basic Accelerometer
  • KD1207 General Purpose Mounting Block
  • ZL1094-M12 Accelerometer cable
  • KA013 Kit Case


Other accessories available

  • KA010 Small Attache Kit Case
  • KD1208 Handlebar Mounting Block
  • KD1206 Small Spike Probe
  • KD1202 Pack of 5 Mounting Studs
  • KD1204 Magnetic Mount
  • KD1212 Cable Tie Wraps
Accelerometer: Piezo-electric (10pc/g)

Ranges:
Acceleration: 0.1 to 1000 ms-2 (0.01 to 100 g)
Velocity: 0.1 to 1000 mms-1

Frequency: Mechanical filter : 10Hz - 1KHz

Memory: non-volatile E2PROM memory which holds calibration data plus storage of 9 spot results.

Keypad: 9 key tactile keypad

Standards: BS6842 Compliance with EMC CE marking

Display: 8 Character LCD Display

Parameters: Acceleration, Velocity, HARM® (Hand Arm Risk Measurement)

Filters: Mechanical and HARM® (Hand Arm Risk Measurement) filter as specified in HSE HS(G)88 publication

Detectors: RMS and Peak

Displays: rms, Lmax, Lpeak, Lav (Linear average value), Elapsed Time

Overload indication (flashing display)

Battery condition indication, Low Battery (Flashing alternate display), Hi/Lo range

Calibration: Simple calibration offset accessed from the keypad and stored in the non-volatile memory

Weight: 250g with batteries

Size: 135 x 62 x 30mm

Batteries: 1 x IEC No 6LR61 (Upto 40 hrs life with Duracel MN1604)